Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vet Res ; 67(2): 169-177, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38143828

RESUMO

Introduction: To understand the prevalence of avian methicillin-resistant Staphylococcus aureus (MRSA) and the current status of drug resistance in Qingdao, a comprehensive molecular epidemiological investigation and analysis of evolutionary relationships of MRSA isolates from broiler and layer chickens and waterfowl was conducted. Material and Methods: One hundred and two avian MRSA strains were identified by multi-locus sequence typing, staphylococcal protein A (spa) and staphylococcal cassette chromosome mec (SCCmec) typing, and whole-genome sequencing. Results: The sequence type (ST) 9-t899-SCCmec IVb type represented the highest proportion of avian-derived MRSA strains (71.57%), with ST398 type strains occasionally observed in broilers and waterfowl. The poultry-derived MRSA strains were all resistant to eight or more antimicrobials. Avian-derived MRSA strains carried 20 resistance genes, 109 virulence genes and 10 plasmids. Strains carrying the cfr oxazolidinone resistance gene were occasionally seen in broiler- and layer-derived MRSA. Single nucleotide polymorphism (SNP) core genome evolution and locus difference analysis showed that the closest strains were all of ST9-t899 type (to which also affiliated the highest number of strains) and this type occurred on all three kinds of poultry farm, but the SNP difference loci between strains of the same type ranged from 0 to 1472. Conclusion: The dominant type of MRSA from different poultry sources in Qingdao is ST9-t899-SCCmec IVb, which is commonly resistant to a variety of antimicrobial drugs and carries a variety of resistance genes and a large number of virulence genes. Sequence type 9-t899 type is widely spread among the three kinds of poultry investigated, but there are differences in affiliations.

2.
Phys Rev Lett ; 131(19): 193801, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38000403

RESUMO

The periodic extension of phase difference is commonly applied in device design to obtain phase compensation beyond the system's original phase modulation capabilities. Based on this extension approach, we propose the application of quasiphase delay matching to extend the range of dispersion compensation for meta-atoms with limited height. Our theory expands the limit of frequency bandwidth coverage and relaxes the constraints of aperture, NA, and bandwidth for metalenses. By applying the uncertainty principle, we explain the fundamental limit of this achromatic bandwidth and obtain the achromatic spectrum using perturbation analysis. To demonstrate the effectiveness of this extended limit, we simulate a quasiachromatic metalens with a diameter of 2 mm and a NA of 0.55 in the range of 400-1500 nm. Our findings provide a novel theory for correcting chromatic aberration in large-diameter ultrawide bandwidth devices.

3.
Biomed Tech (Berl) ; 68(3): 225-240, 2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-36587948

RESUMO

Implant-associated infection is the main reasons for implant failure. Titanium and titanium alloy are currently the most widely used implant materials. However, they have limited antibacterial performance. Therefore, enhancing the antibacterial ability of implants by surface modification technology has become a trend of research. Tantalum is a potential implant coating material with good biological properties. With the development of surface modification technology, tantalum coating becomes more functional through improvement. In addition to improving osseointegration, its antibacterial performance has also become the focus of attention. In this review, we provide an overview of the latest strategies to improve tantalum antibacterial properties. We demonstrate the potential of the clinical application of tantalum in reducing implant infections by stressing its advantageous properties.


Assuntos
Tantálio , Titânio , Titânio/farmacologia , Tantálio/farmacologia , Propriedades de Superfície , Próteses e Implantes , Osseointegração , Materiais Dentários , Antibacterianos/farmacologia
4.
Molecules ; 27(22)2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36431773

RESUMO

To better guide microbial risk management and control, growth kinetic models of Salmonella with the coexistence of two other dominant background bacteria in pork were constructed. Sterilized pork cutlets were inoculated with a cocktail of Salmonella Derby (S. Derby), Pseudomonas aeruginosa (P. aeruginosa), and Escherichia coli (E. coli), and incubated at various temperatures (4-37 °C). The predictive growth models were developed based on the observed growth data. By comparing R2 of primary models, Baranyi models were preferred to fit the growth curves of S. Derby and P. aeruginosa, while the Huang model was preferred for E. coli (all R2 ≥ 0.997). The secondary Ratkowsky square root model can well describe the relationship between temperature and µmax (all R2 ≥ 0.97) or Lag (all R2 ≥ 0.98). Growth models were validated by the actual test values, with Bf and Af close to 1, and MSE around 0.001. The time for S. Derby to reach a pathogenic dose (105 CFU/g) at each temperature in pork was predicted accordingly and found to be earlier than the time when the pork began to be judged nearly fresh according to the sensory indicators. Therefore, the predictive microbiology model can be applied to more accurately predict the shelf life of pork to secure its quality and safety.


Assuntos
Carne de Porco , Carne Vermelha , Animais , Suínos , Microbiologia de Alimentos , Carne Vermelha/microbiologia , Escherichia coli , Modelos Biológicos , Salmonella
5.
Front Microbiol ; 13: 828279, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35401493

RESUMO

Pork is one of the most common foods causing microbial foodborne diseases. Since pork directly enters the market after slaughtering, the control of microbial contamination in the slaughtering processes is the key to ensuring the quality and safety of pork. The contamination level of Escherichia coli, a health-indicator bacterium, can reflect the risk level of potential pathogens. In order to assess the E. coli exposure risk of pork during slaughtering and to identify the key control points, we established an E. coli quantitative exposure assessment model for swine-slaughtering processes in slaughterhouses of different sizes. The model simulation data indicated the E. coli contamination pattern on the surfaces of swine carcasses during slaughtering. The changes in E. coli contamination were analyzed according to the simulation data of each slaughtering process. It was found that the number of E. coli after trimming in big and small slaughterhouses increased to the maximum values for the whole processes, which were 3.63 and 3.52 log10 CFU/100 cm2, respectively. The risk contribution of each slaughtering process to the E. coli contamination on the surface of terminal swine carcasses can be determined by correlation analysis. Because the absolute value of correlation coefficient during the trimming process was maximum (0.49), it was regarded as the most important key control point. This result can be further proved via the multilocus sequence typing of E. coli. The dominant sequence type before trimming processes was ST10. ST1434 began to appear in the trimming process and then became the dominant sequence type in the trimming and pre-cooling processes. The model can provide a theoretical basis for microbial hygiene supervision and risk control in swine-slaughtering processes.

6.
Sensors (Basel) ; 21(22)2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34833595

RESUMO

To study the law that governs the complex movements of the mechanism in the process of automatic weapon operation, the velocity tracking test technology of photon Doppler velocimetry is introduced to accurately measure velocity, displacement and acceleration, on the condition that there are long displacement and rapid velocity change. In the traditional way, out of interference signal time-frequency (TF) transformation draws TF distribution, and then by modulus maxima frequency extraction, comes to the law of velocity change. Due to the influence resulting from the change of fundamental signal as well as that of light intensity signal in the test, based on the TF distribution obtained by TF transformation, the traditional modulus maxima frequency extraction can extract frequency signals, but they show abnormal sudden changes at some moments, making the velocity discontinuous, unsmooth and unreal, which brings obvious errors to the subsequent calculation of acceleration and accurate displacement. Addressing the above-mentioned problems, this paper proposes a ridge extracting correction algorithm based on modulus maxima frequency extraction; this method, based on a large number of experiments where rodless cylinders are used to simulate the motion of a gun automatic mechanism, conducts a detailed calculation and analysis of the experimental results. A comparison of the two algorithms' processing results, in terms of the speed, displacement and acceleration, suggests that the ridge extracting correction algorithm successfully corrects the frequency selection error, which draws a more continuous and, therefore, effective curve of the velocity change, and by so doing, the error of the displacement test (within 1.36 m displacement) is reduced from more than 3.6% to less than 0.58%, and the uncertainty dropped 97.07%. All these show that the accurate measurement of velocity, displacement and acceleration, with sudden and rapid velocity changes considered, is realized successfully.

7.
Front Vet Sci ; 8: 735076, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34676255

RESUMO

The microbial contamination of pork during the slaughter process, especially that of the hygiene indicator bacteria, Escherichia coli, is closely related to the safety and quality of the meat. Some diarrheagenic E. coli can cause serious foodborne diseases, and pose a significant threat to human life and health. In order to ascertain the current status of E. coli and diarrheagenic E. coli contamination during the pig slaughter process in China, we conducted thorough monitoring of large-sized slaughterhouses, as well as small- or medium-sized slaughterhouses, in different provinces of China from 2019 to 2020. The overall positive rate of E. coli on the pork surface after slaughter was very high (97.07%). Both the amount of E. coli contamination and the positive ratio of diarrheagenic E. coli in large-sized slaughterhouses (7.50-13.33 CFU/cm2, 3.44%) were lower than those in small- or medium-sized slaughterhouses (74.99-133.35 CFU/cm2, 5.71%). Combined with the current status of sanitary control in slaughterhouses, we determined that pre-cooling treatment significantly reduced E. coli and diarrheagenic E. coli in pork after slaughter, while microbiological testing reduced E. coli. Based on our monitoring data, China urgently needs to establish relevant standards to better control microbial contamination during pig slaughtering progress. This study provided a theoretical basis for the hygiene quality management of the pig slaughter industry in China.

8.
Front Vet Sci ; 7: 172, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32391385

RESUMO

Chickens contaminated with Campylobacter are a major risk factor for human Campylobacter disease. As a result of the slaughter process, infections should be strictly controlled due to complete exposure of the chickens and the cross-contamination of pathogens. Using @RISK software, quantitative evaluation models of Campylobacter contamination during slaughtering in a large broiler slaughterhouse were constructed. Broiler scalding was set as the starting point of evaluation and four major processes including defeathering, eviscerating, pre-cool rinsing, and splitting-transmission were included. Through the simulation of the constructed model, 90% probability of Campylobacter in 100 g chickens after slaughtering were distributed between 0.3 and 50.2 MPN, which was consistent with simulated actual monitoring data 0-16.6 MPN, indicating that the model shows high credibility. In addition, growth curves of Campylobacter during whole slaughtering showed that contamination significantly increased after defeathering, and increased again after pre-cool rinsing. Using correlation coefficients to analyze the sensitivity of each parameter in the model, it was determined that the concentration of Campylobacter in the pre-cool pond water (correlation coefficient: 0.95) was the most critical risk point of sanitary control in this slaughterhouse. In conclusion, this study is the first to incorporate environmental factors during broiler slaughtering into the risk evaluation of Campylobacter contamination, which provides guidance for the sanitary control and risk management of Campylobacter contamination during broiler slaughtering.

9.
Ultrasonics ; 89: 102-109, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29763793

RESUMO

Iridium-rhodium is generally applied as a thermocouple material, with max operating temperature about 2150 °C. In this study, a ultrasonic temperature measurement system was designed by using Iridium-rhodium (60%Ir-40%Rh) alloy as an acoustic waveguide sensor material, and the system was preliminarily tested in a high-temperature oxidation environment. The result of ultrasonic temperature measurement shows that this system can indeed work stably in high-temperature oxidation environments. The relationship between temperature and delay time of ultrasonic thermometry up to 2200 °C was illustrated. Iridium-rhodium materials were also investigated in order to fully elucidate the proposed waveguide sensor's performance in a high-temperature oxidation environment. This system lays a foundation for further application of high-temperature measurement.

10.
Sensors (Basel) ; 16(11)2016 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-27845726

RESUMO

In this study, an ultrasonic temperature measurement system was designed with Al2O3 high-temperature ceramic as an acoustic waveguide sensor and preliminarily tested in a high-temperature oxidation environment. The test results indicated that the system can indeed work stably in high-temperature environments. The relationship between the temperature and delay time of 26 °C-1600 °C ceramic materials was also determined in order to fully elucidate the high-temperature oxidation of the proposed waveguide sensor and to lay a foundation for the further application of this system in temperatures as high as 2000 °C.

11.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(5): 1440-4, 2015 May.
Artigo em Chinês | MEDLINE | ID: mdl-26415476

RESUMO

To be able to quickly and efficiently identify Enemy camouflaged maneuvering targets in the wild environment, target recognition system was designed based on spectral detection technology and video target recognition method. System was composed of the visible light image acquisition module and static interferometer module. The system used image recognition technology to obtain two dimensional video images of measurement region, and through spectrum detection technology to identify targets. Ultimately, measured target was rebuilt on the corresponding position in the image, so the visual target recognition was realized. After the theoretical derivation, identifiable target function formula of the system was obtained, and based on the functional relationship to complete the quantitative experiments for target recognition. In the experiments, maneuvering target in the battlefield environment was simulated by a car. At different distances, the background was respectively selected to detect a flat wasteland, bushes and abandoned buildings. Obvious target, coated camouflage target and covered disguises target was respectively spectrum detection. Experimental results show that spectrum detection technology can overcome the shortcomings of unrecognized the camouflaged target by traditional image target recognition method. Testing background had some influence on spectrum detection results, and the continuity of the background was conducive to target recognition. Covered disguises target was the hardest to identify in various camouflage mode. As the distance between the target and the system increases, signal to noise ratio of the system was reduced. In summary, the system can achieve effective recognition of camouflaged targets to meet the design requirements.

12.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(9): 2587-90, 2012 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-23240445

RESUMO

Aimed at the mechanical scanning spectroscopy equipment with poor anti-interference and anti-jamming ability, which affects the accuracy of its natural gas pipeline leak detection in the wild, a new type of lateral shearing interferometer system was designed. The system uses a beam splitter to get optical path difference by a mechanical scanning part, and it cancel the introduction of external vibration interference through the linkage between the two beam splitterw. The interference intensity of interference fringes produced was calculated, and analysis of a rotating beam splitter corresponds to the angle of the optical path difference function, solving for the maximum angle of the forward rotation and reverse rotation, which is the maximum optical path range. Experiments using the gas tank deflated simulated natural gas pipeline leak process, in the interference conditions, and the test data of the type WQF530 spectrometer and the new type of lateral shearing interferometer system were comparedt. The experimental results show that the relative error of both systems is about 1% in indoor conditions without interference. However, in interference environment, the error of WQF530 type spectrometer becomes larger, more than 10%, but the error of the new type of lateral shearing interferometer system is still below 5%. The detection accuracy of the type WQF530 spectrometer decreased significantly due to the environment. Therefore, the seismic design of the system can effectively offset power deviation and half-width increases of center wavelength caused by external interference, and compared to conventional mechanical scanning interferometer devices the new system is more suitable for field detection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...